7-day Calibration Error Test

According to the Plain English Guide to the Part 75 Rule, this test \"evaluates the accuracy and stability of a gas or flow monitor's calibration over an extended period of unit operation.\"  See 40 CFR, Part 75, Appendix A, Section 6.3 for details.

ADESTAT

Appendix D and E Status.  These checks determine the unit’s QA status (in or out of control) as related to Appendix D and E tests.  For more information, see the Emissions Reporting Instructions.

Administrative Override

This is one of the errors that may be found in the Evaluation Reports.  These are errors that have been Administratively Overridden by EPA and do not require  a resubmission or any further action.  They are listed in the evaluation report for  informational purposes and have no impact on data submission.

AETB

Air Emission Testing Body. These checks ensure that all CEMS audits and certain other quality assurance testing be performed by an Air Emission Testing Body (AETB) that meets certain competency standards, including experience and knowledge of test methods for individuals conducting the tests. For more information, see the PGVP/AETB Guidance Document.

APPE

Appendix E of Part 75.  These checks validate values and check calculations for Appendix E Tests.  For more information, see the QA and Certification Reporting Instructions.

Barometer Calibration

According to PS 12-B, this test compares the absolute pressure of the barometer of a sorbent trap system against that of a barometer with a NIST-traceable calibration.

Bias Test

According to the Plain English Guide to the Part 75 Rule, this test \"determines whether a monitoring system is biased low with respect to the reference method, based on the RATA results. If a low bias is found, a bias adjustment factor (BAF) must be calculated and applied to the subsequent hourly emissions data. This test is required only for SO2, NOx, Hg, and flow monitoring systems.\"  See 40 CFR, Part 75, Appendix A, Section 3.4 for details.

Calculate Functionality

When entering a new QA Test on the ADD/EDIT QA/CERT TEST DATA screen, you can determine the summary values that EPA will calculate using the Calculate functionality.  You may then choose to use the Client Tool calculated values in your QA Test summary record by employing the Move functionality.  *Note:  The Calculate functionality is intended for users who have only raw test data.  If you use this functionality to generate some calculated values, but not others, there is a potential for errors.

CAPAC

Unit Capacity.  These checks validate values reported in the Unit Capacity record.  Cross checks of this type also ensure consistency between a Unit Capacity Record and other records in the Monitoring Plan.  For more information, see the Monitoring Plan Reporting Instructions.

Check Code

A field in the Evaluation Report files that lists the code associated with an evaluation error.

Check Specifications (Check Specs) Viewer

Accessed through the Help file or through links in the Evaluation Reports, this viewer provides detailed information about evaluation errors.

COMPON

Monitor Component.  These checks validate values reported in Monitor Component, System Component and Analyzer Range records.  Cross checks of this type also ensure consistency between in Monitor Component, System Component, Analyzer Range records and other records in the Monitoring Plan. For more information, see the Monitoring Plan Reporting Instructions.

CONTROL

Unit Control.  These checks validate values reported in the Unit Control record.  Cross checks of this type also ensure consistency between a Unit Control Record and other records in the Monitoring Plan. For more information, see the Monitoring Plan Reporting Instructions.

Critical Error Level 1

This is one of the errors that may be listed in the evaluation reports.  This error indicates that there is a problem with the way the data are reported and it should be possible to correct the error by correcting the reporting.  If you submit data with Critical 1 errors, your data will not be loaded into the EPA database.

Critical Error Level 2

This is one of the errors that may be listed in the evaluation reports.  These errors indicate that there appears to be a deviation from rules and policies, i.e. the data were reported incorrectly or the monitoring or testing was not done in accordance with the requirements.  In the latter case, EPA can decide whether the error should be disregarded.  These errors have no impact on data submission.

CYCLE

Cycle Time Test.  These checks validate values and check calculations for Cycle Time Tests.  For more information, see the QA and Certification Reporting Instructions.

Cycle Time Test

According to the Plain English Guide to the Part 75 Rule, this test \"determines whether a gas monitoring system is capable of completing at least one cycle of sampling, analyzing and data recording every 15 minutes.\"  See 40 CFR, Part 75, Appendix A, Section 6.4 for details.

DAHS

The Data Acquisition and Handling System records all data from the monitoring systems, converts it into the required units of measure, and stores the data.  See 40 CFR, Part 75, Appendix A, Section 4 for details.

DAHS Verification

According to the Plain English Guide to the Part 75 Rule, this ensures that \"all emissions calculations are being performed correctly and that the missing data routines are being applied properly.\"  .See 40 CFR,  §75.59(f) for details.

DAILY

Total Daily Emissions.  These checks validate values and check calculations for Daily Emissions records For more information, see the Emissions Reporting Instructions.

Daily Calibration Error Check

Required daily QA check for gas and stack flow monitors.  See 40 CFR, Part 75, Appendix B for details.

Daily Flow Interference Checks

Required daily QA test to check the functionality of flow monitor electronics.  See 40 CFR, Part 75, Appendix. A, Section 2.2.2.2 for details.

Data entry users

One of the two types of Client Tool users based on the Client Tool's internal security features.  This type of user can modify his or her personal password and contact information using the User Management utility.  This type of user cannot add, edit, or delete the profiles of any other users.

DAYCAL

Daily Calibration Test.  These checks validate values and check calculations for Daily Calibration Tests.  For more information, see the Emissions Reporting Instructions.

DCSTAT

Daily Calibration Status.  These checks determine the QA status of the unit (in or out of control) as related to Daily Calibration tests.  For more information, see the Emissions Reporting Instructions.

DEFAULT

Monitor Default and WAF.  These checks validate values reported in the Monitor Default and WAF  records.  Cross checks of this type also ensure consistency between Monitor Default and WAF records and other records in the Monitoring Plan. For more information, see the Monitoring Plan Reporting Instructions.

DHV

Derived Hourly Value. A calculated emissions value submitted for a parameter at a monitoring location, as described in the ECMPS Emissions Reporting Instructions.

Diagnostic Report

You may be asked to provide this report for a facility by ECMPS Technical Support staff to assist in resolving questions or problems.  The report may be accessed directly from the Help menu, at any time while logged in to the Client Tool, regardless of what module or screen you may have open or what facility's data you may be working with.

ECMPS Client Tool

The Emissions Collection and Monitoring Plan System software used to submit monitoring plans, and QA/Certification and emissions data to the EPA.  This method of submission is mandatory starting in 2009.

Emissions Evaluation Report

The report that is generated each time an emissions file is evaluated.  This report contains the ID number for the unit/stack/pipe that was evaluated, the severity of any errors, the error check codes and descriptions, the beginning and end date and hour for each error, and the number of consecutive hours containing the error.

Emissions Summary Report

This report displays the reported values for certain periods for a facility/location.  For each location in the selected configuration it includes  the Unit/Stack/Pipe ID, the number of hours and days operated, the time operated, the heat input, SO2 mass, CO2 mass, NOX rate, and NOX mass by year, quarter, and year-to-date.

EMTEST

Emissions Test.  Daily tests reported with the emissions data.  For more information, see the Emissions Reporting Instructions.

EMWSI

Weekly System Integrity. These checks validate values and check reported calculations for weekly system integrity checks. For more information, see the Emissions Reporting Instructions.

EMWTS

Weekly Test Summary. These checks validate values and check reported calculations for summary values for weekly system integrity checks. For more information, see the Emissions Reporting Instructions.

EPA Host System

The EPA database that stores official emissions and supporting data.  The Client Tool is able to connect to the EPA Host System to retrieve and submit data.  The EPA Host System replaced the Emissions Tracking System (ETS) on the EPA Mainframe.

Evaluation Period

The period of monitoring plan data evaluated by the Client Tool's Evaluate function.  The evaluation period begins January 1, 2008, or, if the unit began operation after this date, either the Emissions Recording Begin Date or the Unit Monitor Certification Begin Date, whichever is later.

EXTEXEM

QA Extension or Exemption Record.  These checks validate values reported in the Test Extension/Exemption records.  Cross checks of this type also ensure consistency between Test Extension/Exemption records and other records. For more information, see the QA and Certification Reporting Instructions.

F2LCHK

Flow to Load Check.  These checks validate values and check calculations for Flow to Load Check records.  For more information, see the QA and Certification Reporting Instructions.

F2LREF

Flow to Load Reference.  These checks validate values and check calculations for Flow to Load Reference records.  For more information, see the QA and Certification Reporting Instructions.

Fatal Error

This is one of the errors that may be listed in the evaluation reports.  This message indicates that there is an error that has compromised the integrity of the data.  This type of error can also be generated if you attempt to delete a previously reported QA test, event, or extension record without EPA permission.

Feedback Report

This report summarizes information from the EPA concerning your submissions.

FF2LBAS

Fuel Flow to Load Baseline Data.  These checks validate values and check calculations for Flow to Load Baseline Data records.  For more information, see the QA and Certification Reporting Instructions.

FF2LTST

Fuel Flow to Load Test.  These checks validate values and check calculations for Flow to Load test records.  For more information, see the QA and Certification Reporting Instructions.

FFACC

Fuel Flowmeter Accuracy Test.  These checks validate values and check calculations for Fuel Flowmeter Accuracy Tests.  For more information, see the QA and Certification Reporting Instructions.

FFACCTT

Transmitter/Transducer Test.  These checks validate values and check calculations for Transmitter/Transducer Tests.  For more information, see the QA and Certification Reporting Instructions.

File Import Validation Report

This report displays details of validation errors for files imported into the Client Tool.

File submission queue

The list of files that have been assembled in the Client Tool by the user to submit to the EPA.

Filter button

This button is used to filter a list of records so that only the selected record(s) and associated data are viewed.

Flow-to-Load Checks

This is a quarterly QA evaluation that compares the hourly stack flow to load ratio to a reference ratio determined during a RATA.  Also known as \"Stack Flow-toLoad Check.\"  See 40 CFR Part 75, Appendix B, Section 2.2.5 for details.

FORMULA

Monitor Formula.  These checks validate values reported in the Monitor Formula record.  Cross checks of this type also ensure consistency between a Monitor Formula Record and other records in the Monitoring Plan. For more information, see the Monitoring Plan Reporting Instructions.

Four-load NOx Emission Rate Testing and Heat Input Measurement

According to the Plain English Guide to the Part 75 Rule, these provide \"data for a correlation curve of NOx emission rate vs. heat input rate for an Appendix E peaking unit.\"

FUEL

Unit Fuel.  These checks validate values reported in the Unit Fuel record.  Cross checks of this type also ensure consistency between a Unit Fuel Record and other records in the Monitoring Plan. For more information, see the Monitoring Plan Reporting Instructions.

Fuel Flow-to-Load Tests

This is a quarterly QA evaluation that compares the hourly fuel flow rate to load ratio to a reference ratio.  See 40 CFR Part 75, Appendix D, Section 2.1.7 for details.

Fuel Flowmeter Accuracy Test

According to the Plain English Guide to the Part 75 Rule, this test demonstrates that a \"fuel flowmeter can accurately measure the fuel flow rate over the normal operating range of the unit.\"  See 40 CFR Part 75, Appendix D, Sections 2.1.5 and 2.1.6 for details.

FUELFLW

Monitoring System Fuel Flow.  These checks validate values reported in the Monitoring System Fuel Flow record.  Cross checks of this type also ensure consistency between a Monitoring System Fuel Flow Record and other records in the Monitoring Plan. For more information, see the Monitoring Plan Reporting Instructions.

Gas Flow Meter Calibration

According to PS 12-B, this test is designed to ensure that the gas flow meter will give an accurate readout of dry gas volume in standard cubic meters for the particular field application.

GFMCAL

Gas Flowmeter Calibration Test.  These checks validate values and check calculations Gas Flowmeter Calibration Tests.  For more information, see the QA and Certification Reporting Instructions.

Grace period indicator

Specifies if a QA test was conducted during the grace period.

Hierarchically dependent data types

This term refers to the fact that certain types of data in the Client Tool are dependant upon other types.  The QA/Cert data depend on the monitoring plan data, and the emissions data depend on the monitoring plan and the QA/Cert data.  In order to submit data to the EPA, you must first have evaluated any data upon which the data you are submitting depend, i.e. in order to submit emissions files to the EPA, first you must have evaluated the monitoring plan, the QA/Cert data, and the applicable emission files.

HOURAD

Hourly Appendix D.  These checks validate values and check calculations for Appendix D Hourly Emissions records.  For more information, see the Emissions Reporting Instructions.

HOURAE

Hourly Appendix E.  These checks validate values and check calculations for Appendix E Hourly Emissions records.  For more information, see the Emissions Reporting Instructions.

HOURAGG

Hourly Aggregation.  These checks compare reported summary values against those recalculated by the Client Tool.  For more information, see the Emissions Reporting Instructions.

HOURAPP

Hourly Apportionment.  These checks validate and recalculate apportioned hourly values.  For more information, see the Emissions Reporting Instructions.

HOURCV

Hourly Calculated Value.  These checks recalculated hourly values and compare reported to recalculated values.  For more information, see the Emissions Reporting Instructions.

HOURGEN

Hourly General.  These checks validate monitoring plan, QA test and Emissions Data.  Many of these checks indicate that problems were found by other specific check types.  For more information, see the Emissions Reporting Instructions.

HOURMHV

Monitor Hourly Value.  These checks validate values and check calculations for Monitor Hourly Value records.  For more information, see the Emissions Reporting Instructions.

HOUROP

Hourly Operating Data.  These checks validate values and check calculations for Hourly Operating Data records For more information, see the Emissions Reporting Instructions.

IMPORT

Data Import.  These checks provide basic validation of values reported in an XML file (MP, QA or EM) during Import.  Some errors will prevent import of values.

Informational Error

This is one of the errors that may be listed in the evaluation reports.  These messages are intended to identify unusual aspects of a source's report that are not necessarily errors.  EPA would like the user to look over these informational errors to confirm that they do not indicate problems with the data.  These errors have no impact on data submission.

Leak Check (Flow)

For differential pressure flow monitors, this check of all sample lines must be performed during each QA operating quarter.  See 40 CFR, Part 75, Appendix B, Section .2.2.2 for details.

LEE unit (Low Emitting EGU)

A unit which meets the qualifications of 63.10000(c) as a low emitting unit.

LINEAR

Linearity Test.  These checks validate values and check calculations for Linearity Test records For more information, see the QA and Certification Reporting Instructions.

Linearity Check

According to the Plain English Guide to the Part 75 Rule, this test \"determines whether the response of a gas monitor is linear across its range.\".  See 40 CFR, Part 75, Appendix B, Section 2.2.1  for details.

LINSTAT

Linearity Status. These checks determine the unit’s QA status (in or out of control) as related to Linearity tests. For more information, see the Emissions Reporting Instructions.

LME

Low Mass Emissions.  These checks validate values and check calculations for Hourly records for LME units.  For more information, see the Emissions Reporting Instructions.

LME Generation Report

An error report produced by the LME generation process, which allows users to generate a quarterly emissions file for LME units after entering hourly operating data and quarterly fuel flow data.  Information found in the report includes the unit/stack/pipe ID, the severity of the error, and the error check code and description.

LME unit (Low Mass Emissions unit)

According to 40 CFR PART 72 this term refers to an \"affected unit that is 'gas-fired' or 'oil fired', and that qualifies to use the low mass emissions excepted methodology in §75.19.\"

LOAD

Unit Load.  These checks validate values reported in the Unit Load record.  Cross checks of this type also ensure consistency between a Unit Load Record and other records in the Monitoring Plan. For more information, see the Monitoring Plan Reporting Instructions.

Long-term cold storage

According to 40 CFR PART 72 this term refers to the \"complete shutdown of a unit intended to last for an extended period of time (at least two calendar years) where notice for long-term cold storage is provided under §75.61(a)(7).\"

MATSCHV

MATS Calculated Hourly Value. These checks recalculate hourly values and compare reported values to recalculated values. For more information, see the Emissions Reporting Instructions.

MATSDHV

MATS Derived Hourly Value. A calculated emissions value submitted for a MATS parameter at a monitoring location, as described in the ECMPS Emissions Reporting Instructions.

MATSGFM

MATS Hourly Gas Flow Meter. These checks validate values reported for hourly gas flow meter records.

MATSHOD

MATS Operating Hour. These checks validate values and check reported calculations for hourly data for MATS parameters. For more information, see the Emissions Reporting Instructions.

MATSMHV

MATS Monitor Hourly Value. These checks validate values and check calculations for MATS Monitor Hourly Value records. For more information, see the Emissions Reporting Instructions.

MATSTRN

MATS Sampling Train. These checks validate values and check calculations for sorbent trap sampling train records. For more information, see the Emissions Reporting Instructions.

MATSTRP

MATS Sorbent Trap. These checks validate values and check calculations for sorbent trap records. For more information, see the Emissions Reporting Instructions.

Menu Panel

This panel is located in the lower left corner of each Client Tool screen.  It is used to toggle between different modules of the Client Tool.

METHOD

Monitor Method.  These checks validate values reported in the Monitor Method record.  Cross checks of this type also ensure consistency between a Monitor Method Record and other records in the Monitoring Plan. For more information, see the Monitoring Plan Reporting Instructions.

Module Action Panel

This panel is located in the upper left corner of each Client Tool screen.  It contains links to various actions that can be taken in a module.

Monitoring Plan Evaluation Report

This report is created after the monitoring plan is evaluated.  Information found in the report includes the unit/stack ID, the severity of any error found, the category of the error, and the error check code and description.

Monitoring Plan Printout Report

This report is a printout of an entire monitoring plan, including all relevant data contained in the Client Tool.  It is important to note that if your local Client Tool database has not been synchronized with the EPA Host System, the information in this report may not include the most recent data from the EPA Host System.

MONLOC

Monitor Location.  These checks validate values reported in the Monitor Location record.  Cross checks of this type also ensure consistency between a Monitor Location Record and other records in the Monitoring Plan. For more information, see the Monitoring Plan Reporting Instructions.

MONPLAN

Monitoring Plan.  These checks ensure that a Monitoring Plan has affected Units in the CAMD system, as well as validate values reported in the Monitor Plan Comment record For more information, see the Monitoring Plan Reporting Instructions.

Non-Critical Error

This is one of the errors that may be listed in the evaluation reports.  These are minor errors that indicate small calculation errors or possible reporting errors that have a minimal impact on interpretation of the data and no implication for other data.  These errors have no impact on data submission.

NOx Emission Rate Testing at one or more unit loads

According to the Plain English Guide to the Part 75 Rule, this test \"determines fuel-and unit-specific NOx emission factors for LME units (optional).\"

Online Offline Calibration Tests

This test demonstrates that offline calibration testing is acceptable for the tested CEM analyzer.  It compares offline and online calibration test results.  See 40 CFR, Part 75, Appendix B, Section 2.1.1.2 for details.

ONOFF

Online/Offline Calibration Test.  These checks validate values and check calculations for Online/Offline Calibration Test records.  For more information, see the QA and Certification Reporting Instructions.

PEMS Accuracy Check

A three-run relative accuracy audit for a Predictive Emissions Monitoring System (PEMS).

PGVP

Protocol Gas Verification Program. EPA Protocol gases are used in calibration tests to determine if CEMS are accurately measuring pollutant concentrations. The PGVP checks ensure that power plants are using Protocol gases procured from vendors that participate in the PGVP. For more information, see the PGVP/AETB Guidance Document.

Primary Element Inspection

This is a required certification and periodic QA check for orifice nozzle or venture type fuel flowmeters.  See 40 CFR, Part 75, Appendix D, Section 2.1.6(c) for details.

PROGRAM

Unit Program.  These checks validate values reported in the Unit Program record.  Cross checks of this type also ensure consistency between a Unit Program Record and other records in the Monitoring Plan.  For more information, see the Monitoring Plan Reporting Instructions.

QA Cert Events Report

This report is a summary of QA Cert events.  This report contains the unit/stack ID, the event code, date, and hour, the system and component ID/type, the required tests, the conditional data begin date and hour, and the date and hour of the last test complete.

QA Operating Quarter

As defined in 40 CFR, Part 72, this is \"a calendar quarter in which there are at least 168 unit operating hours…or for a common stack or bypass stack, a calendar quarter in which there are at least 168 stack operating hours.\"

QA Status Analysis

As part of the emissions data evaluation, the ECMPS client tool determines for each hour of measured data whether the reporting monitoring system is in control.  This \"QA Status\" indicates whether the monitor or system has successfully passed all required QA tests in the proper timeframe.

QA Supplemental Data

This is test history data.  This data includes information such as unit/stack, test number, component ID/type, the begin and end date and hour of the test, the span scale, the reason for the test, the test result, and the test submission availability.

QA/Cert Test Detail Report

This report is generated through the QA/Cert Test Report link.  This report contains summary statistics, run data, and any additional information related to the selected test.

QA/Cert Test Evaluation Report

This report is created after a QA/Cert test is evaluated.  Information found in the report includes the unit/stack ID, the test type, number, date, and hour, the system/component ID or type, the severity of any error found, and the error check code and description.

QA/Cert Test Summary Report

This report is generated through the QA/Cert Test Report link.  It is a summary of the current QA/Cert test information.  Information contained in this report includes the component ID/type, the system ID/parameter, the test type that was evaluated, the load levels, the test number, date, and hour, the reason the test was conducted, the test result (passed/failed), and the date it was submitted to EPA.

QACERT

QA/Certification Event.  These checks validate values reported in the QA/Certification Event record.  Cross checks of this type also ensure consistency between a QA Cert Event Record and other records.  For more information, see the QA and Certification Reporting Instructions.

QUAL

Monitor Qualification.  These checks validate values reported in the Monitor Qualification record.  Cross checks of this type also ensure consistency between a Monitor Qualification Record and other records in the Monitoring Plan.  For more information, see the Monitoring Plan Reporting Instructions.

QUALLEE

Qualification LEE. These checks validate values reported in the LEE Qualification record. For more information, see the Monitoring Plan Reporting Instructions.

RATA

Relative Accuracy Test Audit.  According to the Plain English Guide to the Part 75 Rule, this test \"compares emissions data recorded by a CEMS to data collected concurrently with an EPA emission test method.\"  See 40 CFR, Part 75, Appendix B, Section 2.3.1 for details.

RATSTAT

RATA Status.  These checks determine the unit’s QA status (in or out of control) as related to RATA tests.  For more information, see the Emissions Reporting Instructions.

Recalculated Values

These values are calculated by the Client Tool during the evaluation of QA/Cert tests and emissions data.  They are determined using raw data and are displayed on the screen of the Client Tool for diagnostic purposes.  During an evaluation the Client Tool compares the values that were entered or imported, to the values that it recalculates.  If the difference between the two exceeds a specific tolerance an evaluation error is generated.  If the values that were entered or imported differ from EPA's recalculated values, this may indicate an error in entering the data or generating the data from your DAHS.

SEVNDAY

Seven Day Calibration Demonstration.  These checks validate values and check calculations for Seven Day Calibration Test records.  For more information, see the QA and Certification Reporting Instructions.

SPAN

Monitor Span Value.  These checks validate values reported in the Monitor Span record.  Cross checks of this type also ensure consistency between a Monitor Span Record and other records in the Monitoring Plan. For more information, see the Monitoring Plan Reporting Instructions.

Stack Flow-to-Load

See \"Flow-to-Load Check\"

Submission Access Report

This report is accessed from the Submit module.  Information available in this report includes the facility ID and name, the date and time information for the facility was last updated in SMS/CBS, the date and time error suppression records were last updated by EPA, the last time information on the Host was updated (if your Client Tool is not in sync, this information may not be correct in the report), and the submission availability and evaluation status of monitoring plan, QA test and certification, test extension/exemption, and emissions data.

Submission Details/Receipt Report

This report displays the various stages of processing a file undergoes when submitted, starting with \"Preparing to submit data to EPA Host System\" and ending with whether or not the file submission process was successful.

Submission Log

This log displays a list of all the submissions made from your Client Tool to the EPA Host System.

Submission Summary Report

This report displays the current status of each submission for a facility.  Information available in this report includes the submission ID and the date and time the file was submitted, the unit/stack/pipe ID, the file type, stage status, and a record of who submitted the file.

Submit Log Report

This report displays the details of the submission process highlighted in the grid from your Client Tool to the EPA Host System.

Synchronization

Synchronization is the process by which ECMPS ensures that the baseline data in the Client Tool represent the data on the EPA Host System.

SYSTEM

Monitor System.  These checks validate values reported in the Monitor System record.  Cross checks of this type also ensure consistency between a Monitor System Record and other records in the Monitoring Plan.  For more information, see the Monitoring Plan Reporting Instructions.

System Integrity Check

According to the Plain English Guide to the Part 75 Rule, \"for mercury CEMS equipped with a converter, this test verifies that the converter is working properly.\"  See 40 CFR, Part 75, Appendix B, Section 2.6 for details.

System Managers

One of the two types of Client Tool users based on the Client Tool's internal security features.  This type of user can add, edit, and delete the profiles of users and determine whether passwords are required for login.

Temperature Sensor Calibration

According to PS 12-B, this test calibrates the in-stack temperature sensor against a reference sensor.

TEST

General Test.  These checks validate values and check calculations for general test records.  Numerous types of QA tests are checked by these checks.  For more information, see the QA and Certification Reporting Instructions.

Test Extensions and Exemptions Report

This report is used to view information related to QA/Cert test extensions and exemptions.  This report contains the unit/stack ID, the extension/exemption type and reporting period, the system and component ID/type, the span scale code, the fuel code, and the hours used.

Test History Report

This report contains a list of all of the QA tests submitted for a facility since January 2003.  This report contains the unit/stack ID, test number, component ID/type, test duration, span scale, the reason for the test and the test results, the grace period indicator, and the submission availability.

Three-Level System Integrity

This test assesses the transport and measurement of oxidized Hg by a Hg CEMS across three injection levels.

Transmitter Transducer Test

This test determines the accuracy of transmitters and/or transducers that are part of an orifice, nozzle or venture type fuel flowmeter.  It must be performed for initial certification and periodic QA.  See 40 CFR, Part 75, Appendix D, Section 2.1.6.1 for details.

UNITDEF

Unit Default Test.  These checks validate values and check calculations for Unit Default Test records.  For more information, see the QA and Certification Reporting Instructions.

WAF

Wall effects adjustment factor.

Weekly System Integrity

System integrity Check means a test designed to assess the transport and measurement of oxidized Hg by a Hg CEMS. See 40 CFR Part 63 Appendix A Section 3.1.14.

Working Panel

This is the largest panel on the screen.  It is located to the right of the Module Action and Menu Panels.

WSISTAT

Weekly System Integrity Status. These checks determine the unit’s QA status (in or out of control) as related to Weekly System Integrity Tests. For more information, see the Emissions Reporting Instructions.

XML