Are there guidelines for reporting RATA data?

The following table contains information from the reporting instructions with guidelines for reporting RATA data:

 

Reference Method Code

RATA Summary Data

Flow Rata Run Data

RATA Traverse Data

CO2 or O2 Reference Method Code/ Stack Diameter/ Stack Area

Number of Traverse Points

Calculated/ Rectangular Duct WAF

Default WAF

Average Velocity With Wall Effects/ Calculated Wall Effects Adjustment Factor

Point Used Indicator/

Replacement Velocity

Yaw Angle

Pitch Angle

2

N

N

N

N

Do not report these records

D2H

N

N

N

Y

Do not report these records

M2H

Y

N

Y (Calculated WAF)

N

Y

(report this record and the associated RATA Traverse data only for runs in which a WAF is calculated)

Y

(if point used to calculate a WAF)

N

N

2J

N

Y

Y (Rectangular Duct WAF from monitoring plan)

N

Do not report these records

2F

Y

N

N

N

N

N

Y

Y

2G

Y

N

N

N

N

N

Y

N

2FH

Y

N

Y

(if using a calculated WAF);

N

(if using a default WAF)

Y

(if using a default WAF);

N

(if using a calculated WAF)

Y

(for any run in which a WAF is calculated)

Y

(if point used to calculate a WAF)

Y

Y

2GH

Y

N

Y

(if using a calculated WAF);

N

(if using a default WAF)

Y

(if using a default WAF);

N

 (if using a calculated WAF)

Y

(for any run in which a WAF is calculated)

Y

(if point used to calculate a WAF)

Y

N

2FJ

Y

N

Y (Rectangular Duct WAF from monitoring plan)

N

N

N

Y

Y

2GJ

Y

N

Y (Rectangular Duct WAF from monitoring plan)

N

N

N

Y

N

 

 


Tags: data, QA data